Schedule 5S Pipe 24 Inch (DN600 mm) Dimensions, Weight & Thickness

Schedule 5S Pipe 24 Inch DN600

This reference provides the key dimensional data for Schedule 5S Pipe 24 Inch (DN600), including outside diameter, inside diameter, wall thickness, and listed weight. Use the table and supporting notes to coordinate large-diameter stainless steel piping layouts, fabrication details, and procurement reviews.

For related design work, connect this reference with your site’s resources on pipe schedules, NPS and DN designations, pipe fittings and flanges, and pipe weight calculations. Those references help users move from a dimensional check to a coordinated piping assembly.

Schedule 5S Pipe 24 Inch (DN600 mm) is a stainless steel pipe size used in large-diameter piping systems where corrosion resistance and lighter wall thickness are required. This pipe size is commonly referenced under ANSI/ASME B36.19, the standard used for stainless steel pipe dimensions.

For this size, the pipe has an outside diameter (OD) of 610 mm, an inside diameter (ID) of 598.92 mm, and a wall thickness of 5.54 mm. The listed pipe weight is 82.58 kg/m, while the weight including water is 364.16 kg/m.

Schedule 5S Pipe 24 Inch (DN600 mm) Dimension Table

Pipe Size NPS DN Outside Diameter (OD) Inside Diameter (ID) Wall Thickness Weight
Schedule 5S Pipe 24 Inch DN600 610 mm 598.92 mm 5.54 mm 82.58 kg/m

What Is Schedule 5S Pipe?

Schedule 5S is a thin-wall stainless steel pipe schedule listed in ASME B36.19. The ā€œSā€ designation is generally used for stainless steel pipe schedules. Compared with heavier pipe schedules, Schedule 5S offers lower wall thickness and lighter weight, which can be helpful for fabrication, transport, and installation in suitable service conditions.

Pipe schedule selection should always be checked against project requirements such as design pressure, temperature, corrosion allowance, piping code, and service environment.

24 Inch Schedule 5S Pipe Data

  • Standard: ANSI/ASME B36.19
  • Pipe Type: Stainless Steel Pipe
  • NPS: 24 Inch
  • DN: DN600
  • OD: 610 mm
  • ID: 598.92 mm
  • Wall Thickness: 5.54 mm
  • Pipe Weight: 82.58 kg/m
  • Weight Including Water: 364.16 kg/m

Common Uses of 24 Inch Schedule 5S Pipe

24 inch Schedule 5S stainless steel pipe may be used in applications where a large flow path and corrosion-resistant material are needed. Typical uses may include:

  • Water treatment and utility systems
  • Industrial stainless steel process piping
  • Low-pressure transfer lines
  • Food and beverage production systems
  • Chemical plants and general fabrication work

Why DN600 Pipe Dimensions Matter

Many users search for DN600 pipe dimensions to verify layout space, support design, transportation limits, fabrication details, and compatibility with related piping components. For large-diameter pipe, accurate dimensions are important for spool coordination, structural loading, and installation planning.

Knowing the correct 24 inch Schedule 5S pipe dimensions also helps engineers, detailers, estimators, and buyers compare this pipe with other schedules when reviewing wall thickness, internal flow area, and total pipe weight.

NPS 24 and DN600 Explained

NPS stands for Nominal Pipe Size in inches, while DN stands for Diameter Nominal in millimeters. For this pipe size:

  • NPS 24 = inch-based nominal pipe size
  • DN600 = metric nominal designation

Even though DN is shown in metric form, the actual outside diameter must still be checked from the pipe standard. For this size, the OD is 610 mm.

Reference for Schedule 5S Pipe 24 Inch

This page provides a quick dimensional reference for engineers, designers, students, fabricators, and procurement teams looking for Schedule 5S Pipe 24 Inch (DN600 mm) data in a simple format.

Reference Standard: ANSI/ASME B36.19 stainless steel pipe dimensions.

How to Read the Schedule 5S Pipe Data

The listed outside diameter (OD) is the external size used when checking clearances, supports, clamps, insulation space, and connections to fittings. The inside diameter (ID) describes the available flow passage. The difference between these dimensions is associated with the pipe wall, which is reported separately as wall thickness.

The listed pipe weight is useful for estimating the dead load of the empty pipe and for reviewing handling or support requirements. The separate weight including water value represents a filled-pipe condition and should be considered when reviewing support loads, equipment connections, and installation planning.

Schedule, Size, and Component Coordination

Schedule 5S identifies the stainless steel pipe wall designation; it is not a complete design-pressure rating. Final selection requires review of the applicable piping code, material specification, design pressure, temperature, corrosion allowance, joining method, and service environment.

When coordinating this pipe with valves, reducers, elbows, flanges, and other components, confirm that the connection dimensions and material requirements match the project specification. A dimensional match alone does not verify pressure, corrosion, welding, or operating suitability.

Useful Related References

  • Link to a pipe schedule guide for comparisons between stainless steel wall designations.
  • Link to an NPS to DN reference for users converting between nominal inch and metric designations.
  • Link to a pipe fittings and flange dimensions guide for connection and spool-layout coordination.
  • Link to a pipe weight or filled-pipe load reference for preliminary support and handling reviews.
  • Link to the site’s DWG reference resources so detailers can access the associated CAD file alongside the dimensional data.

Frequently Asked Questions

What are the dimensions of Schedule 5S Pipe 24 Inch?

The listed dimensions are an outside diameter of 610 mm, an inside diameter of 598.92 mm, and a wall thickness of 5.54 mm.

What is the NPS and DN designation for this pipe?

This pipe is identified as NPS 24 and DN600. These are nominal designations, so the actual outside diameter should be checked against the applicable pipe dimension reference.

What is the listed weight of the pipe?

The listed pipe weight is 82.58 kg/m. The source also lists a water-filled weight of 364.16 kg/m; use the appropriate condition when reviewing support and installation loads.

Does Schedule 5S define the pipe pressure rating?

No. The schedule identifies a pipe wall designation and does not by itself establish a complete allowable pressure rating. Pressure and service suitability require review of the design conditions, material, applicable piping code, and project requirements.

Which standard is associated with these stainless steel pipe dimensions?

The source identifies ANSI/ASME B36.19 as the dimensional reference for this stainless steel pipe size.

Why are DN600 dimensions important during drafting?

DN600 dimensional data supports layout checks, spool coordination, support planning, component selection, fabrication, and installation reviews. The pipe should still be checked against the connected fittings, flanges, valves, and project specifications.