Schedule 10S Pipe 8 Inch (DN200) Dimensions, Weight & Thickness

Schedule 10S Pipe 8 Inch DN200

This reference page is intended for engineers, designers, drafters, fabricators, estimators, and procurement teams checking Schedule 10S pipe 8 inch (DN200) dimensions. Use the table below as a quick dimensional reference, then confirm the project specification, material grade, manufacturing requirements, and applicable design code before ordering or using the pipe in a system.

The page also supports practical drafting and layout work by bringing the nominal size, outside diameter, wall thickness, inside diameter, and unit weight together in one place. The downloadable DWG file can be useful when preparing piping arrangements or checking how this pipe size relates to connected fittings and components.

Schedule 10S pipe 8 inch (DN200) is a stainless steel pipe size commonly used in piping design, fabrication, drafting, and engineering reference work. This page provides the standard dimensions, wall thickness, inside diameter, and weight per meter for NPS 8 Schedule 10S pipe based on ASME B36.19.

8 Inch Schedule 10S Pipe Dimensions

  • Nominal Pipe Size (NPS): 8 inch
  • Diameter Nominal (DN): DN200
  • Outside Diameter (OD): 219.1 mm
  • Wall Thickness: 3.76 mm
  • Inside Diameter (ID): 211.58 mm
  • Pipe Weight: 19.97 kg/m
  • Pipe Weight Filled With Water: 55.11 kg/m
  • Reference Standard: ASME B36.19
  • Pipe Type: Stainless Steel Pipe

Schedule 10S Pipe 8 Inch Data Table

Pipe Size DN OD (mm) Wall Thickness (mm) ID (mm) Weight (kg/m)
8 inch 200 219.1 3.76 211.58 19.97

What Does Schedule 10S Mean?

Schedule 10S is a stainless steel pipe schedule covered by ASME B36.19. For the same nominal pipe size, the outside diameter remains fixed while the wall thickness changes with the schedule. The ā€œSā€ designation is commonly used for stainless steel pipe schedules.

Typical Uses of 8 Inch Schedule 10S Pipe

NPS 8 Schedule 10S pipe is commonly used in stainless steel piping systems for industrial plants, utility services, food and beverage facilities, water-related systems, and fabrication work where corrosion resistance and dimensional accuracy are important.

Why Pipe Weight Matters

Pipe weight per meter is useful for transport planning, lifting studies, support design, structural loading, fabrication estimates, and installation planning. In stainless steel piping systems, accurate weight data helps improve material handling, support spacing, and total project cost estimation.

8 Inch Schedule 10S Pipe Calculation Notes

The listed weight is based on standard stainless steel pipe dimensions using the outside diameter and wall thickness of the pipe. Actual product weight may vary slightly depending on manufacturing tolerance, material grade, and supplier standard.

Frequently Asked Questions

What is the outside diameter of 8 inch Schedule 10S pipe?

The outside diameter is 219.1 mm.

What is the wall thickness of DN200 Schedule 10S pipe?

The wall thickness is 3.76 mm.

What is the inside diameter of NPS 8 Schedule 10S pipe?

The inside diameter is 211.58 mm.

How much does 8 inch Schedule 10S pipe weigh?

The approximate weight is 19.97 kg/m.

Which standard covers this pipe size?

This dimension data is based on ASME B36.19 for stainless steel pipe.

Conclusion

Schedule 10S pipe 8 inch (DN200) has an outside diameter of 219.1 mm, wall thickness of 3.76 mm, inside diameter of 211.58 mm, and a weight of 19.97 kg/m. It is a useful reference for piping design, drafting, estimating, and stainless steel fabrication work.

How to Read This Pipe Reference

NPS 8 and DN200 identify the same nominal pipe size in inch-based and metric terminology. These labels are nominal designations, so they should not be treated as a direct statement of the measured inside diameter. For layout and connection work, the listed outside diameter is especially important because fittings, flanges, supports, and other components must be coordinated with the pipe system.

The schedule identifies the wall-thickness selection for this stainless steel pipe size. It is not a material grade, corrosion allowance, pressure rating, or complete purchasing specification. Material selection and service suitability require the applicable project documents and engineering review.

Using the Dimensions in Design and Drafting

The outside diameter and wall thickness help establish the listed inside diameter, while the weight value supports material takeoffs, handling plans, support checks, and general estimating. Designers should distinguish between the pipe’s own unit weight and the additional loads from contents, insulation, valves, fittings, supports, thermal effects, and other system components.

For CAD work, compare the downloaded drawing with the project model, connection details, and the manufacturer’s supplied product information. A reference drawing is useful for geometry and coordination, but it does not replace a certified dimensional document or an approved fabrication drawing.

Related Pipe Reference Topics

Readers working with this entry may also need the site’s related references for pipe dimensions, pipe schedules, stainless steel pipe, flange dimensions, pipe fittings, and piping CAD/DWG resources. These topics provide useful next steps when coordinating a complete piping assembly rather than reviewing the pipe barrel alone.

Additional Questions About 8 Inch Schedule 10S Pipe

Is Schedule 10S a material grade?

No. Schedule 10S identifies a stainless steel pipe schedule and its associated dimensional selection. The material grade, product specification, and service requirements must be checked separately.

Can the listed dimensions be used to select fittings?

They can support preliminary coordination, but fittings, flanges, valves, and other components should be selected against their applicable dimensional standards and the approved project specification. Confirm compatibility before fabrication or installation.

Does the listed pipe weight include the contents of the pipe?

The page distinguishes the pipe weight from the listed weight for pipe filled with water. Other operating loads, such as insulation, fittings, supports, and process contents, require separate consideration.

Is the downloadable DWG a substitute for a fabrication drawing?

No. The DWG is a drafting and reference resource. Review it against the project model, connection details, supplier documentation, and approved fabrication requirements before issuing construction documents.

Why might delivered pipe weight differ from the reference value?

Actual product weight can vary with manufacturing tolerances, material grade, surface condition, length, and supplier practice. Use certified supplier documentation for purchasing, shipping, and final weight control.